High-cycling transformer design
Support storage operating profiles with inverter-duty transformer solutions designed for repeated cycling and efficient operation.

Select a photo to explore. Open the main image for a full-size view.
Storage & energy integration
Integrated BESS transformer solutions for utility-scale storage and high-cycling duty. Turnix connects transformer, inverter, switchgear, protection, and control requirements into coordinated power blocks, with skid-mounted and containerized deployment options.
Turnix technical capabilities
Explore the portfolio and configuration options. Turnix’s technical team will help align the equipment with your application, site, and performance requirements.
The integrated platform is configured for inverter compatibility and modular deployment.
| Parameter | Turnix capability |
|---|---|
| Transformer power range | 1–20 MVA |
| Primary voltage | Up to 34.5 kV |
| Secondary voltage | 480–900 V, inverter-compatible |
| Cooling | ONAN / ONAF |
| Design duty | Inverter duty; high-cycling storage applications |
| Loss / efficiency design | Engineered for low losses and efficient operation; guaranteed values established for the selected duty |
| Package formats | Skid-mounted or containerized |
| Integrated power block | Transformer, MV/LV switchgear, protection and control panels |
| Delivery approach | Factory-assembled and pre-tested |
A separate transformer selection pathway supports higher primary voltage requirements. Its envelope is distinct from the integrated platform above.
| Parameter | Turnix capability |
|---|---|
| Transformer range | 1–10 MVA |
| Primary voltage range | 11–69 kV |
| Construction | Oil-immersed |
| Electrical functions | Voltage transformation, isolation, impedance matching, harmonic mitigation, and voltage regulation |
| System coordination | Batteries, power conversion, switchgear, cooling, controls, and fire suppression |
Transformer MVA, battery energy in MWh, and usable AC output are separate design inputs. Turnix coordinates the transformer-only or integrated-storage pathway around the required duty.
Design & configuration
Electrical, mechanical, and installation requirements come together in the selected Turnix solution.
Support storage operating profiles with inverter-duty transformer solutions designed for repeated cycling and efficient operation.
Combine the transformer, MV/LV switchgear, protection, and control panels in a factory-assembled package to reduce site interfaces and installation work.
Skid-mounted and containerized options support modular project delivery. Batteries, conversion, cooling, controls, and fire suppression can be coordinated within the wider system scope.
Testing & documentation
Integrated packages are factory-assembled and pre-tested, with the equipment schedule and acceptance plan defined for the project.
Coordinate protection, controls, inverter compatibility, and communications. Agree functional acceptance criteria across the transformer and storage system.
Prepare installation interfaces, technical documentation, site acceptance requirements, and operating responsibilities before deployment.
Turnix coordinates the technical submittals and deliverables needed for equipment review, delivery, and operation.
Prepare your RFQ
Share the application, electrical duty, and site requirements. We’ll help turn them into a clear equipment scope.
Peak management, backup, renewable integration, export control, or another defined use case.
AC kW/MW, usable kWh/MWh, discharge duration, cycle profile, availability objective, and life assumptions.
Connection voltage, interconnection requirements, operating modes, metering, protection, and EMS/SCADA interfaces.
Location, footprint, environment, fire/access requirements, permitting, and required system documentation.
Applications
The integrated platform spans 1–20 MVA, with primary voltage up to 34.5 kV and inverter-compatible secondary voltage from 480–900 V.
A separate 1–10 MVA oil-immersed transformer pathway covers primary voltages from 11–69 kV. Turnix will review the appropriate configuration for your project.
No. Transformer apparent power and battery energy capacity are different parameters. Battery MWh, usable output, and operating duration are specified separately.
Your Turnix team
Application review, customization, project coordination, and after-sales support.
Portfolio ranges describe available solution pathways. Final rating combinations, availability, certifications, testing, and supply scope are confirmed in the project-specific proposal.
Connect with our team for equipment selection, engineering coordination, and lifecycle support.